DIPLOMAT 2004
Alarm
050265c
050238B
DO NOT turn this switch OFF in an
emergency situation.
Maintenance
7 • 274
Procedures to Take During an Alarm:
1. Turn off all gas appliances, (stove, heaters, furnace),
extinguish all flames and smoking material. Evacuate,
leave doors and windows open.
2. Turn off the primary valve on the LP tank.
3. Determine and repair the source of the leak. Have a qualified
professional determine and repair the source of the leak.
CAUTION: Do Not re-enter until the problem is
corrected.
WARNING: Do not operate the remote LP disconnect
switch during an alarm. This may cause a spark that
can ignite the fuel. Turn off the primary LP valve on the
LP tank.
Potential Sources of LP Gas Leaks When Operating the
Motorhome:
• Cooktop Burners
• Oven
• Furnace
• Refrigerator
Alarm Mute:
Press the Test-Mute button when the detector is in alarm.
1. The red LED will continue flash and the alarm will beep every
30 seconds until the gas level has dropped to a safe level.
2. The LED will flash green until the end of the Mute cycle.
3. If dangerous gas levels return before the end of the Mute cycle,
the alarm will beep four times and return to phase 1.
4. After two minutes the detector will return to normal operation (solid
green) or resound the alarm if dangerous levels of gas remain in the area.
Fault Alarm:
Should the microprocessor sense a fault in the gas detector, a fault alarm
will sound twice every 15 seconds. The LED will alternately flash red to
green and the MUTE switch will not respond to any command. The gas
detector must be repaired or replaced.
1. Vacuum the dust off the detector cover weekly (more frequently in
dusty locations) using the soft brush attachment of the vacuum.
2. Do not spray cleaning agents or waxes directly onto the front
panel. This action may damage the sensor, cause an alarm or
cause a detector malfunction.
• Water heater
• Defective Regulator
• Defective LP-Gas Connection
• Portable Propane Powered Equipment