Galley Filter; The Water Pump Is Noisy Or Rough In Operation; The Water Pump Is Rapid Cycling - Monaco DIPLOMAT 2004 Owner's Manual

Table of Contents

Advertisement

DIPLOMAT 2004

Galley Filter

6 • 250
The water pump will not shut-off or runs when the faucet is closed:
• Check to see if the fresh water tank fill valve is completely
closed.
• Check output side (pressure) plumbing for leaks and inspect for
a leaky toilet or valves.
• Look for loose drive assembly or pump head screws.
• Are the valves or the internal check valve held open by debris or
is the rubber swollen?

The water pump is noisy or rough in operation:

• Check for plumbing which may have vibrated loose.
• Does the mounting surface multiply noise (flexible)?
• Check for mounting feet that are loose or compressed too tight.
• Look for loose pump head to motor screws.

The water pump is rapid cycling:

• Look for restrictive plumbing/flow restrictors in the faucets or shower
heads.
The water filter is located under the galley sink. For winterization
purposes, the filter head may have been installed with the diverter cap in
place. In this case remove the diverter cap and store for winterization.
Install the cartridge by following the instructions on the cartridge.
The internal filter is designed to remove particles and organisms as
small as ½ micron*. As water passes through the water filter, impurities
are trapped in the pores of the micro-pure coating restricting the flow of
water. When the flow of water is restricted the cartridge should be
replaced.
The life of the filter will vary depending on the purity of the
040492
incoming water and the quantity used. If the cartridge is not changed,
the flow will eventually stop entirely. Even if the flow of water is not
reduced, change the cartridge at least once a year for
reliable filter performance.
130345
*One micron is one millionth of one meter.
NOTE: Change the filter at least
once a year.