A double pole "pass-through" relay trips when AC power is supplied to the input terminals to trans-
fer AC power through the inverter to the two circuit breakers located on the front of the inverter. The
two breakers supply AC power to various outlets and the microwave. When AC power is supplied to
the inverter, the internal battery charger will "ramp up" battery charge voltage. A 20 second time delay
allows charge stabilization before pass through AC power is supplied to the breakers.
The inverter uses a battery temperature sensor to adjust charge voltage. When the battery tempera-
ture rises the sensor sends this information to the inverter to decrease charge voltage. Voltage com-
pensation with temperature variation is necessary to keep charge voltage at optimum values. The sen-
sor is secured to the terminal of the battery.
Battery Capacity and Idle Mode are adjustable. The set-up mode must be entered to change a set-
ting.
To Enter the Set-Up Mode:
• Press and hold the SETUP button for five seconds. LED lamps will change from green to
red.
• If a setting change does not occur within five seconds, the remote returns to the user menu.
• Use the Remote Owner's Manual to cross-reference the LED lights to their respective indi-
cation.
Idle Mode:
Setting the IDLE mode controls the threshold (in watts) that turns the inverter on from search mode.
The adjustment range is 5 to 100 watts. The factory setting is five watts. Press the INVERT button
to change the settings.
Battery Capacity:
Setting the proper battery capacity tailors the internal charger to optimum values. The Factory
setting is 400. Press the CHARGE button to change the settings.
.