Advertisement

Separate thermostats are used for LP-Gas and AC electric. The
thermostat controls the power to the module board. At 130° F, the
thermostat will open, extinguishing the burner. If the thermostat fails, a High
Temperature safety limit switch will open. The safety switch will require
manual reset.
CAUTION: If the High Temperature safety limit should
open, discontinue using the water heater. Have the water
heater inspected by a qualified technician to determine the
cause of the over temperature condition.
The bypass valve is located at the back of the water heater. Turning the
valve to BYPASS stops water from entering the cold water inlet of the water
heater. Turn the valve to BYPASS when winterizing. For normal operation,
turn valve so that handle points to NORMAL FLOW.