Battery Specification - House; Approximate Hours At Ampere Load; Battery State Of Charge Vs. Voltage / Specific Gravity - Monaco DIPLOMAT 2004 Owner's Manual

Table of Contents

Advertisement

DIPLOMAT 2004

BATTERY SPECIFICATION - HOUSE

12 Volt Chassis*
Group 31p - LHD (2 each)
6 Volt Domestic**
U2200 (4 each)
*Batteries connected in parallel. **Battery connections are made in a Series/Parallel connection.
†CCA Ratings are at 0º F. These are the minimum requirements.
U2200 (4 each)
* Loads conducted @ 80° F. with battery fully charged to 1260 per cell specific
gravity. Voltage to maintain 1.75 Volts per cell (10.5 Volts for 12 Volt battery).
Voltage Reading: Battery fully charged at rest for one hour.
8 •322
Application

Approximate Hours at Ampere Load*

5 AMPS
55

Battery State of Charge vs. Voltage / Specific Gravity

Voltage
Specific Gravity
12.66
1.265
12.45
1.225
12.25
1.190
12.05
1.145
11.90
1.100
Ah (20hr)
CCA†
750
450
10 AMPS
15 AMPS
20 AMPS
22
12.5
State of Charge
100%
75%
50%
25%
0%
ELECTRICAL SYSTEMS - HOUSE
RC (25A @ 80° F)
minutes
180 X 2 = 360
75Amp@
80º F. = 230 Min.
25 AMPS
9.1
7
Depth of Charge
0%
25%
50%
75%
100%

Hide quick links: