Figure 22:
Configuration of the
operating data transferred
via RS-232 to the network
Figure 23:
Toolbar for the routing
configuration
Note
The graphical user interface
Configuration of the input data for the RS-232 routing
 On the Interfaces menu, click RS-232 [0] to open the dialog box for the RS-232
configuration.
 Click the MELSEC-WS to RS-232 button on the left to display the routing
configuration for the input data.
Basically this dialog is divided into three areas: Available data 1), RS-232 data 2) and
Tag names 3). The upper left corner of the dialog holds the toolbar 4).
The toolbar
The toolbar contains buttons for the following actions (from left to right):
 The Load user configuration and Save user configuration buttons allow you to
load and/or save a configuration in XML format, including the used tag names. If
you load a configuration, all previously made changes that have not been saved will
be lost. You can not undo this action.
 Using the Import and Export buttons you can import and export the tag names
used as a CSV file (comma separated values). This allows you to import and use
the assigned tag names in a Programmable controller program.
The Import button is only available for the RS-232 to MELSEC-WS routing
configuration.
Chapter 5
48