Mitsubishi Electric WS0-CPU0 Operating Manual page 192

Melsec ws series, safety controller setting and monitoring tool
Table of Contents

Advertisement

Chapter 9
Table 81:
Dual-channel evaluation
Note
189
Logic programming – Function blocks
The following truth table describes the discrepancy conditions for the dual-channel
equivalent and the dual-channel complementary input evaluation:
Evaluation
Input
Input
type
1A
1B
Equivalent
0
0
1
1
x
Complementary
0
0
1
1
x
*1
If the discrepancy time is active (> 0), the discrepancy timer is restarted on the first signal change
resulting in a discrepant status. If the discrepancy time is inactive (= 0), the discrepancy timer does
not start, i.e. a timeout will never occur.
*2
Unchanged = Last status is preserved.
*3
If the correct sequence has been observed.
For the change between the different states of the dual-channel evaluation the
following rules apply:
A dual-channel evaluation can only change to Active (Enable output changes from
Low to High), if ...
 since the last Active status at least once the status was Inactive, i.e. it is not
possible to switch from Active to Discrepant and back to Active, and
 the discrepancy time has not elapsed or the discrepancy time is deactivated, and
A discrepancy error (timeout) is reset, if the Active status has been reached, i.e. the
Enable output changes to High.
When defining values for the discrepancy time the following must be observed: The
discrepancy time ...
 must be greater than the logic execution time,
 has a tolerance of +/- 10 ms in addition to the logic execution time. The logic
execution time depends on the number and type of function blocks used and is
shown in the Setting and Monitoring Tool in the logic editor on the FB info tab and
also in the report.
Discrepancy
Evaluation
*1
timer
status
0
0
Inactive
< Discrepancy
1
Discrepant
time
< Discrepancy
0
Discrepant
time
1
0
Active
≥ Discrepancy
x
Error
time (timeout)
1
0
Inactive
< Discrepancy
0
Discrepant
time
< Discrepancy
1
Discrepant
time
0
0
Active
≥ Discrepancy
x
Error
time (timeout)
Enable output
Discrepancy
error output
0
Unchanged
0
Unchanged
0
Unchanged
*3
1
0
0
Unchanged
0
Unchanged
0
Unchanged
*3
1
0
*2
*2
*2
0
1
*2
*2
*2
0
1