Chapter 5
Exercise
Note
Note
35
The graphical user interface
5.5.3

Exercise for configuring the connected devices

 The selection tree in the Elements selection window can be expanded and
collapsed by means of a mouse click. Optional: Right-click a device and select Edit
current element in the context menu. Assign a user-defined Internal item number
if you want to. This Internal item number is stored for this device.
 Select some devices from the list and drag them into the Parking area.
The Parking area serves to increase clarity. You can compile all required devices
here so that you do not forget any of them during the configuration. Alternatively, you
can drag the devices directly from the Elements selection window into the
Configuration area.
 Then drag a device from the Parking area into the Configuration area.
 If the Configuration area does not contain a module with suitable free
inputs/outputs, the device cannot be placed there. In this case, place at least one
hardware module with inputs or outputs, e.g. WS0-XTIO or WS0-XTDI, in the
Configuration area.
 When the device is moved over suitable free inputs or outputs, they light up green.
The Setting and Monitoring Tool automatically considers the required number of
inputs or outputs. Drop the device on a suitable position. The device icon is now
displayed in the view at this point.
Certain elements can not be connected to all modules:
 Dual channel elements can only be connected to safe modules.
 Pure safety elements can only be connected to safe modules.
 Drag the device to other suitable inputs or outputs or back into the Parking area.
 Delete the device by right-clicking the device icon and clicking Remove in the
context menu. Alternatively, you can use the mouse to drag the device to the
trashcan at the bottom left of the Configuration area.
 A device can be parameterized when it is located in the Parking area or in the
Configuration area. Right-click a device in the Parking area or Configuration
area and select Edit... from the context menu or double-click a device. The
Element settings window is opened. Depending on the type of device you can:
– assign a tag name (identifying name for the element)
– set evaluation parameters for the element, for example the discrepancy time,
ON-OFF filter or OFF-ON filter, connection to a test output, test pulses
enabled/disabled, etc.
(See also Section 5.5.6).
 Close the Element settings window by clicking OK.