Flexi Link Stations: Station X View And Process Image - Mitsubishi Electric WS0-CPU0 Operating Manual

Melsec ws series, safety controller setting and monitoring tool
Table of Contents

Advertisement

Figure 76:
Flexi Link input bits from
Station A in the logic editor
of another station
Note
Flexi Link
Using data from the Flexi Link network
You will find all available information from the other stations in the Flexi Link network
in the Inputs tab of the logic editor under the symbol of the respective station's CPU
module:
You can use these inputs just as any other input.
 Inputs can be used several times.
 Inputs that are already used at least once in this station's logic are displayed green.
 The Flexi Link inputs are displayed with their respective tag names. You can edit
the tag names in the Flexi Link station X view of the originating station (see
Section 7.4.5).
7.4.5

Flexi Link stations: Station X view and process image

In the Flexi Link station X view you can do the following:
 Edit the tag names for the bits and bytes that this station sends to the Flexi Link
network.
 Set the default values for this station's process image bits to Low or High (see also
Section 7.4.6).
 To open the Flexi Link station X view press the corresponding button in the
toolbar. If the station contains also a network module, this button can be found in
the Network module menu.