RS-232 and IR connectors
Figure 6 shows how to wire the RS-232 and IR connector.
Tx/Rx
Pins
Figure 6.
RS-232 and IR Connector Wiring
NOTES:
The length of exposed wires is important. The ideal length is
3/16 inch (5 mm).
If the stripped section of wire is longer than 3/16 inch, the
exposed wires may touch, causing a short circuit.
If the stripped section of wire is shorter than 3/16 inch,
wires can be easily pulled out even if tightly fastened by the
captive screws.
Do not tin the power supply leads before installing them in the
connector. Tinned wires are not as secure in the connector and
could be pulled out.
HDMI connectors
Use a LockIt Lacing Bracket to securely fasten each HDMI cable to the
switcher as follows.
1.
Plug the HDMI cable into
the panel connection (
2.
Loosen, but do not remove,
the HDMI connection
mounting screw from the
panel enough to allow the
LockIt to be placed over
it (
).
2
3.
Place the LockIt lacing
bracket on the screw and
against the HDMI connector
(
), then tighten the screw
3
to secure the bracket.
ATTENTION:
Do not overtighten the HDMI connector mounting screw. The
shield it fastens to is very thin and can easily be stripped.
Ne serrez pas trop la vis de montage du connecteur HDMI.
Le blindage auquel elle est attachée est très fin et peut
facilement être dénudé.
IR Device
Rx
Tx
Gnd
Tx
Rx
Gnd
RS-232 Device
3 3 3
).
1
1 1 1
3
4 4 4
5 5 5
XTP II CrossPoint 1600, 3200, and 6400 • Installation
2 2 2
15