Extron electronics DTP CrossPoint 108 4K Setup Manual

Extron electronics DTP CrossPoint 108 4K Setup Manual

Scaling presentation matrix switcher
Hide thumbs Also See for DTP CrossPoint 108 4K:

Advertisement

Setup Guide
Matrix Switcher
DTP CrossPoint 4K Series
Scaling Presentation Matrix Switcher
68-2368-51 Rev. B
10 19

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics DTP CrossPoint 108 4K

  • Page 1 Setup Guide Matrix Switcher DTP CrossPoint 4K Series Scaling Presentation Matrix Switcher 68-2368-51 Rev. B 10 19...
  • Page 2 Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano AVVERTENZA: Il simbolo, , se usato sul prodotto, WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated serve ad avvertire l'utente della presenza di tensione dangerous voltage within the product’s enclosure that may non isolata pericolosa all'interno del contenitore present a risk of electric shock...
  • Page 3 All trademarks mentioned in this guide are the properties of their respective owners. The following registered trademarks, registered service marks, and trademarks are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on Terms of Use page at www.extron.com):...
  • Page 4 FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5 Conventions Used in this Guide Notifications ATTENTION: • Risk of property damage. • Risque de dommages matériels. NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make working with the application easier. Software Commands Commands are written in the fonts shown here: ^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C [01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]...
  • Page 7: Table Of Contents

    Contents ........ 1 ......22 Introduction Remote Control About this Guide ......1 Selected SIS Commands .... 22 About the DTP CrossPoint 4K Establishing a Network Series ........... 2 (Ethernet) Connection .... 22 DTP Input and Output Number of Connections ..23 Signals ........
  • Page 8 viii DTP CrossPoint 4K Series • Contents...
  • Page 9: Introduction

    Introduction This section gives an overview of the Extron DTP CrossPoint 4K Series matrix switchers and describes their features. Topics that are covered include: About this Guide • • About the DTP CrossPoint 4K Series About this Guide NOTE: For more information on subjects in this guide, see the DTP CrossPoint 4K Series User Guide and the IPCP Pro Series User Guide, at www.extron.com.
  • Page 10: About The Dtp Crosspoint 4K Series

    (differentiated by their audio and control capabilities) for a total of 12 models: Matrix sizes — • DTP CrossPoint 108 4K — 10x8 DTP matrix switcher DTP CrossPoint 86 4K — 8x6 DTP matrix switcher • DTP CrossPoint 84 4K — 8x4 DTP matrix switcher •...
  • Page 11: Dtp Input And Output Signals

    Equipment configurations — • DTP CrossPoint 4K IPCP SA — Includes a stereo audio amplifier and a built-in Extron IPCP Pro control processor • DTP CrossPoint 4K IPCP MA — Includes a 70 V mono audio amplifier and a built-in Extron IPCP Pro control processor DTP CrossPoint 4K —...
  • Page 12: Installation

    (see figure 2, 4, 6, and 8) but with fewer connectors. • The DTP CrossPoint 82 is similar to the DTP CrossPoint 84, (see figure 3, 5, 7, and 9) but with fewer connectors. Video Inputs and Outputs DTP CROSSPOINT 108 4K COM 1 COM 2 COM 3 DIGITAL I/O...
  • Page 13 COM 1 COM 2 COM 3 DIGITAL I/O RS-232 100V AV LAN 2 AV LAN 3 Tx Rx Tx Rx Tx Rx Tx Rx G Tx Rx G REMOTE RTS CTS LINK LINK S/PDIF OVER TP IR/SERIAL RELAYS DIGITAL I/O RS-232 RESET Tx Rx G...
  • Page 14 HDMI outputs (see figure 2 figure 3 on page 4 and on page 5) — Plug HDMI video displays (or DVI with HDMI appropriate adapters) into these ports. See connectors to secure the connectors to the enclosure with a LockIt HDMI Cable Lacing Bracket. The following table identifies the HDMI outputs by matrix size.
  • Page 15: Audio Inputs And Outputs

    Audio Inputs and Outputs DTP CROSSPOINT 108 4K COM 1 COM 2 COM 3 DIGITAL I/O AV LAN 2 AV LAN 3 +48V Tx Rx RTS CTS Tx Rx G Tx Rx G 1 2 3 4 G MIC/LINE IR/SERIAL...
  • Page 16: Serial And Ir Insertion Connections

    Expansion port on an optional Extron DMP 128 ProDSP Digital Matrix Processor. Link LED — Lights to indicate that the port is connected to a compatible device. Serial and IR Insertion Connections DTP CROSSPOINT 108 4K COM 1 COM 2 COM 3 DIGITAL I/O...
  • Page 17: Control Connections

    Inputs Matrix Inputs 10x8 5B, 6B, 7, 8 3B, 4B, 5, 6 3B, 4B 1B, 2B Control Connections DTP CROSSPOINT 108 4K COM 1 COM 2 COM 3 DIGITAL I/O AV LAN 2 AV LAN 3 +48V Tx Rx RTS CTS...
  • Page 18: Switcher Reset

    Tx Rx G connector for remote control of the switcher (see RS-232 and IR connectors on page 15 to wire the connector). Switcher Reset DTP CROSSPOINT 108 4K COM 1 COM 2 COM 3 DIGITAL I/O AV LAN 2 AV LAN 3...
  • Page 19: Power

    In the event of a complete system reset, the passwords convert to the default, which is no password. Power DTP CROSSPOINT 108 4K COM 1 COM 2 COM 3...
  • Page 20 Place the LockIt Lacing Bracket on the screw and against the HDMI connector (see figure 13, , on page 11), and then tighten the screw to secure the bracket. ATTENTION: • Do not overtighten the HDMI connector mounting screw. The shield it fastens to is very thin and can easily be stripped.
  • Page 21 Crossover cable (see figure 14 • on page 12) — • AV LAN and LAN ports — UTP or STP for direct connection between the switcher and a connected computer. NOTES: • Do not use standard telephone cables. Telephone cables do not support Ethernet or Fast Ethernet.
  • Page 22 For the DTP ports only — Extron recommends the following practices to achieve full transmission distances up to 330 feet (100 m) and reduce transmission errors. Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best performance: XTP DTP 24/1000 Non-Plenum 1000' (305 m) spool 22-236-03 XTP DTP 24P/1000 Plenum 1000' (305 m) spool...
  • Page 23 NOTE: When using cable in bundles or conduits, consider the following: • Do not exceed 40% fill capacity in conduits. • Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles. •...
  • Page 24: Front Panel

    RS-232 and IR connectors Figure 16 shows how to wire the RS-232 and IR connector. RS-232 Device RS-232 Device Rx Tx Tx/Rx Pins Tx Rx IR Device Figure 16. RS-232 and IR Connector Wiring NOTE: The length of exposed wires is important (see the NOTES audio connectors above for more information).
  • Page 25: Front Panel Operations

    Front Panel Operations This section describes simple DTP CrossPoint matrix switcher operation from the front panel. Topics that are covered include: Creating a Tie • Recalling a Preset • • Viewing Ties Assigning a Logo to an Output • Viewing and Adjusting Volume and Mic Volume •...
  • Page 26: Recalling A Preset

    Press and release the desired output buttons. Amber indicates video and audio tie. Green indicates video only tie. Red indicates audio only tie. Green indicates the need ENTER to confirm the change. Press and release the button. All button indicators turn Enter off.
  • Page 27: Assigning A Logo To An Output

    Assigning a Logo to an Output The switcher can display a logo on one or more of the scaled outputs. The following table identifies the TP outputs by matrix size. Matrix Outputs Matrix Outputs 10x8 5 through 8 3 through 6 3 and 4 1 and 2 NOTES:...
  • Page 28: Setting The Front Panel Locks (Executive Modes)

    Setting the Front Panel Locks (Executive Modes) The matrix switcher has three levels of front panel security lock that limit the operation of the switcher from the front panel. The three levels are: • Lock mode 0 — The front panel is completely unlocked. Lock mode 1 —...
  • Page 29: Selecting Lock Mode 2 Or Toggling Between Mode 2 And Mode 0

    Selecting Lock Mode 2 or Toggling between Mode 2 and Mode 0 NOTES: • If the switcher is in Lock mode 0 or mode 1, this procedure selects mode 2. The , and buttons blink Video Audio twice. • If the switcher is in Lock mode 2, this procedure selects mode 0 (unlocks the switcher).
  • Page 30: Remote Control

    Remote Control This section describes using the remote control features of the DTP CrossPoint 4K Series. Topics that are covered include: Selected SIS Commands • Installing and Starting the Control Programs • • Accessing the HTML Pages Selected SIS Commands You can use SIS commands for operation and configuration of the SIS Command and Response Table for Matrix switchers (see...
  • Page 31: Number Of Connections

    Number of Connections A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and Telnet connections. When the connection limit is reached, the switcher accepts no new connections until some have been closed. No error message or indication is given that the connection limit has been reached.
  • Page 32: Sis Command And Response Table For Matrix Switcher Commands

    DTP CrossPoint 4K Series • Remote Control...
  • Page 33 DTP CrossPoint 4K Series • Remote Control...
  • Page 34 DTP CrossPoint 4K Series • Remote Control...
  • Page 35 DTP CrossPoint 4K Series • Remote Control...
  • Page 36: Installing And Starting The Control Programs

    Installing and Starting the Control Programs The following programs are available on the Extron website: Digital Signal Processor (DSP) Configurator program — Required for full operation of switcher DSP functions. It also provides some limited control of the switcher non-DSP functions. See the DTP CrossPoint 4K Series User Guide and the program Help file for more information.
  • Page 37 Installing the programs The DSP Configurator, version 2.11 or newer, and PCS, version 3.4 or newer are available on the Extron website. Download and install both programs as follows: NOTE: This procedure was written using Microsoft Internet ® Explorer . Depending on the browser you use, some steps or ®...
  • Page 38: Starting The Product Configuration Software

    Starting the Product Configuration Software Click Start > Programs > Extron Electronics > Extron Product Configuration Software > Extron Product Configuration Software The Product Configuration Software opens to the Device Discovery screen (see figure 20). 1 1 1 1 1 1 1 1...
  • Page 39: Starting The Dsp Configurator Program

    Extron recommends connection via an Ethernet LAN port for the DSP Configurator program. Start the DSP Configurator program, as follows: Click Start > Programs > Extron Electronics > DSP . The DSP Configurator Configurator > DSP Configurator Startup screen opens (see figure 22).
  • Page 40 * The output 1 amplifier block is not present on non-IPCP models. Figure 23. DSP Configurator, DTP CrossPoint 108 Selected NOTE: The DSP Configurator has a software lock that protects the complex DSP audio adjustments, making them unavailable for selection in PCS. This protects the DSP settings against inadvertent changes made by the more basic PCS audio adjustment capabilities.
  • Page 41: Accessing The Html Pages

    Accessing the HTML Pages NOTES: • If your Ethernet connection to the matrix switcher is unstable, try turning off the proxy server in your Web browser. In Microsoft Internet Explorer, click Tools > , uncheck the Internet Options > Connections > LAN Settings ...
  • Page 42 Enter the appropriate user name and administrator or user password in the field and click Password NOTE: The factory configured passwords for all accounts on this device have been set to the device serial number. In the event of a complete system reset, the passwords convert to the default, which is no password.
  • Page 43 In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
  • Page 44 Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876...

This manual is also suitable for:

Dtp crosspoint 84 4kDtp crosspoint 86 4kDtp crosspoint 4k seriesDtp crosspoint 4k ipcp saDtp crosspoint 4kDtp crosspoint 4k ipcp ma ... Show all

Table of Contents