4
Use
to highlight Auto Sequence, then press
H
.
D
5
Use
to highlight Template, then press
A D
6
Use
to highlight Horizontal, then press
H
.
7
On the Auto Sequence screen, press
transfer the default pattern into the START ID and
STOP ID.
A
8
Use
to highlight Start ID; then press
JKL
BCAD
9
Use
,
change the default ID to 03A-A01.
N
Press
when you are done.
D
10 Use
to highlight Stop ID; then press
JKL
BCAD
11 Use
,
change the default ID to 03A-B06.
N
Press
when you are done.
L
12 Press
Sample List. You should see a list of 12
sequential fiber IDs: 03A-A01 through 03A-B06. If the
tester beeps instead of showing the list, check your
Start and Stop IDs for the problems listed below.
2-24
13 Press
H
.
14 Press
If the ID sequence is invalid, check the following:
J
Default to
H
.
H
, and
to
H
.
H
, and
to
I
to leave the sample list.
If the tester shows an error message, check your Start
and Stop IDs for the problems listed below.
N
when you are done setting up the list. The list
is saved in the tester's internal memory.
Verify that the types of characters in each position
match between the start and stop IDs. For example,
using the letter "O" as the third character in the Start
ID and the number "0" as the third character in the
Stop ID is not allowed.
Verify that you are not using the characters / # * - . , : [ ]
space or accented characters as incrementing
characters. You may use these characters in IDs, but
they must match between the Start and Stop IDs.
Verify that the Start and Stop IDs have the same
numbers of characters.
Verify that the Stop ID is not sequentially greater than
the Start ID. For example, using 25 as the Start ID and
10 as the Stop ID is not allowed.
Verify that the Start and Stop IDs do not generate a
sequence with more than 3000 IDs.