Creating A Custom Outlet Configuration - Fluke DTX-1800 Technical Reference Handbook

Dtx series cable analyzer
Hide thumbs Also See for DTX-1800:
Table of Contents

Advertisement

To create a custom twisted pair limit:
1
Turn the rotary switch to SETUP; then select Twisted
Pair.
2
Select Test Limit, press
J
3
Press
Create.
4
On the Custom screen, select Name; then use the text
editing screen to enter a name for your custom limit.
N
Press
when you are done.
5
On the Custom screen, select Use Default Values From,
select a test limit group; then select a limit as a baseline
for your custom limit.
6
The Custom screen shows other settings on multiple
tabs for the twisted pair limit. Use
H
to select settings to change. Use
among the tabs.
See page 3-3 for details on twisted pair test settings.
7
From the Custom screen, press
creating the limit. The tester saves the custom limit in
the Custom list, with asterisks (*) before and after the
name.
J
More; then select Custom.
AD
BC
to move
N
when you are done

Creating a Custom Outlet Configuration

Creating a Custom Outlet
Configuration
You can create up to nine custom outlet configurations. A
custom outlet configuration includes the following settings:
Custom outlet name
Baseline outlet configuration for default settings
Testing enabled or disabled for each wire pair
To create a custom outlet configuration:
1
Turn the rotary switch to SETUP; then select Twisted
Pair.
2
Select Outlet Configuration; then select Custom.
J
3
Press
and
4
On the Custom screen, select Name; then use the text
editing screen to enter a name for your custom
configuration. Press
5
On the Custom screen, select Use Default Values From;
then select an outlet configuration as a baseline for
your custom configuration.
Custom Test Settings
Create.
N
when you are done.
12
-continued-
12-3