Collision rate averaging above 5 %
Duplex mismatch on the network.
Too many stations within the collision domain.
Faulty hub, switch, NIC, or other device.
Cabling is too long.
Errors detected (any rate above 0 %)
Cabling is too long.
Faulty cabling (such as intermittent wiring faults, cabling of the wrong category, or poor quality cabling)
Faulty or marginal network interface card (NIC).
Faulty or misconfigured hardware or software.
Electrical noise source near cabling. Use the impulse noise test to check for noise. See page 3-34.
Duplex mismatch on the network.
Bad grounding for network components.
Broadcast rate too high (acceptable rates vary among networks)
Faulty or misconfigured hardware or software.
Table 11-2. Diagnosing Low-Level Network Problems (cont.)