Fluke DTX-1800 Technical Reference Handbook page 194

Dtx series cable analyzer
Hide thumbs Also See for DTX-1800:
Table of Contents

Advertisement

DTX Series CableAnalyzer
Technical Reference Handbook
2
3
7-36
1
A
Overall result for the test.
B
Events on the fiber, each event's status, and the distance to each event. See
Table 7-3 on page 7-37.
E
: The event's measured value is within the limit. A yellow checkmark
means there is a warning for the result. To see the warning, highlight the
event; then press
i
: The event has no PASS/FAIL limit in the selected test limit. The
measurement is provided for informational purposes.
F
: The event's measured value exceeds the limit.
C
J
Press
D
K
Press
D
amd129f.eps
Figure 7-19. Event Table Features
L
View Details.
to view the OTDR trace.
to view details for the highlighted event. See page 7-42.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dtx-ltDtx-1200Dtx-cltDtx-clt certifiberDtx-elt

Table of Contents