The DTX-PLA001 universal permanent link adapter has a
removable personality module. These may be changed to
customize the adapter for different jack configurations.
To change the personality module (refer to Figure 1-9):
1
Ground yourself by touching a grounded, conductive
surface.
2
Remove the link interface adapter from the tester.
3
Use your fingers to unscrew the screw on the
personality module.
Store the module in its original, static protection bag.
Put the new module in place and tighten the screw with
your fingers.
W
Tighten the screw snugly with your fingers only.
Do not overtighten. Doing so can damage the
module or the end of the cable.
Caution
F1
F2
F3
EXIT
TEST
ENTER
SAVE
AUTO
TEST
SINGLE
SETUP
TEST
SPECIAL
MONITOR
FUNCTIONS
TALK
Figure 1-9. Changing the Personality Module on a DTX-
PLA001 Adapter
The optional DTX-PLCAL automated calibration kit lets you
calibrate your permanent link adapters to compensate for
physical changes that occur over time to the adapter's cable
and other components. Contact Fluke Networks for more
information.