DTX Series CableAnalyzer
Technical Reference Handbook
Setting
Length
Reflective Event Loss
Non-reflective Event Loss
Event Reflectance
Overall Loss
Overall Attenuation Coefficient
Segment Attenuation Coefficient
12-8
Table 12-1. Settings for Custom OTDR Limits
Enter a maximum length for the cabling.
Enter a maximum value for connector loss. A typical value is 0.75 dB.
Enter a maximum value for splice loss. A typical value is 0.3 dB.
Enter a maximum reflection value for a single event.
Enter a maximum value for the loss of all components and fiber in the cabling at
each wavelength tested.
Enter a maximum value of attenuation per kilometer for the entire length of the
cabling at each wavelength tested.
Enter a maximum value of attenuation per kilometer for a fiber segment in the
cabling at each wavelength tested.
The segment attenuation coefficient for shorter segments (50 m to 500 m,
depending on wavelength and fiber characteristics) may not be measurable.
Description
Note