Looking At Otdr Test Results - Fluke DTX-1800 Technical Reference Handbook

Dtx series cable analyzer
Hide thumbs Also See for DTX-1800:
Table of Contents

Advertisement

DTX Series CableAnalyzer
Technical Reference Handbook

Looking at OTDR Test Results

The tester offers four different views of OTDR test results:
summary results, an OTDR trace, an event table, and
detailed results.
2
3
D
E
7-28
A
Overall result for the test:
1
PASS: All measurements are within limits.
FAIL: One or more measurements exceed the limit.
B
The limit, fiber type, wavelengths, and fiber end number (1 or 2) used
for the test. See Table 7-1 on page 7-18.
C
Measurements taken (see Table 7-2) and each measurement's status:
E
: The measured value is within the limit. A yellow checkmark means
there is a warning for the result. To see the warning, press
Events; then press
i
: The measurement has no PASS/FAIL limit in the selected test limit and
is provided for informational purposes.
F
: The measurement exceeds the limit.
D
Shows the OTDR trace.
F
E
Shows the Event Table. See page 7-36.
amd153f.eps
F
Shows the limits used for the test.
Figure 7-16. OTDR Results Screen
Reading the OTDR Results Screen
The OTDR Results screen, which appears when the test is
finished, is described in Figure 7-16.