Printronix ThermaLine Series Programmer's Reference Manual page 72

Thermaline series
Table of Contents

Advertisement

Example
The following program will produce the Incremental Alphanumeric data
example at the bottom of the previous page. The program elements are also
defined. (Refer to the command format on page 4–22.)
ALPHA
I;1;1;0;0;001;RPT3;RST9;*A01*
I;3;1;0;0;001;RPT1;RST0;*B01*
STOP
where:
I;1;1;0;0;001;RPT3;RST9;*A01*
I;3;1;0;0;001;RPT1;RST0;*B01*
4–28
Incremental alphanumeric command;
SR of 1; SC of 1;
VE and HE are 0;
001 stepmask increments by 1;
RPT3 repeats each field value 3 times;
RST9 prints and increments each field 9 times before resetting;
*A01* is the starting value.
Incremental alphanumeric command;
SR of 1; SC of 1; VE and HE are 0;
001 stepmask increments by 1;
RPT1 repeats each field value once;
RST0 prints and increments each field 0 times before resetting;
*B01* is the starting value.