Printronix ThermaLine Series Programmer's Reference Manual page 218

Thermaline series
Table of Contents

Advertisement

I–2/5 Command Format
BARCODE
I–2/5 [CD]; [VSCAN;] [MAG;] [Hn[.m];] [BFn;L;] [DARK;] SR; SC
[(D)data field(D)]
[PDF [;LOC] [;FONT]]
STOP
I–2/5 German Command Format
BARCODE
I25GERMAN; [VSCAN;] [MAG;] [Hn[.m];] [BFn;L;] [DARK;] SR; SC
[(D) data field (D)]
[PDF [;LOC] [;FONT]]
STOP
BARCODE
I–2/5 CD
VSCAN
MAG
5–80
The Bar Code command; enter BARCODE.
Designates bar code type Interleaved 2/5; enter I–2/5.
To calculate and plot the optional modulo–10 check
digit with the bar code symbol automatically, enter
CD. For the German variation of the bar code, enter
I25GERMAN, instead of I-2/5 (the checksum digit is
always automatically calculated for German I-2/5).
Optional parameter to orient the bar code structure
vertically. To select a vertical bar code, enter VSCAN.
If VSCAN is not entered, the bar code is oriented
horizontally.
Optional parameter to magnify (horizontally expand)
the bar code symbol. The magnification default value
is X1. For the German variation of the bar code, the
default magnification is X1A. As required for
scanning, enter a magnification value to increase the
magnification. Increasing the magnification adjusts
printed character density. You can also use XR or XRD
as defined on page 5–4.