PTX_Setup Command Description

Purpose
Enables the host to control PSA printer resources common to all
emulations.
Mode
All modes (Normal, Quiet, etc.)
Format
(cc) PTX_SETUP
<category–> [<parameter;value:> ...<parameter;value:>|<parameter;value:>.
:
:
<category–> [<parameter;value:> ...<parameter;value:>|<parameter;value:>.
PTX_END
(cc)
PTX_SETUP
<category – >
<parameter;value:> Parameter and value pair for the current category. See
3–2
The Special Function Control Character.
This cc is NOT the PGL SFCC. It is the "setup" SFCC
and is set under the Maint/Misc configuration menu.
The trigger command. Must appear in capital letters.
Once the trigger is detected, all unprintable characters
and spaces (i.e., characters less than 21 hex) are
ignored.
This selects which category or type of command is
being entered: CONFIG, DISK_IO, ENGINE,
FORMAT or TEST_CHK. All categories must appear
in capital letters and must be followed by a dash (–).
the listing of categories, valid parameters and ranges of
values beginning on page 3–4. The parameter and
value must be separated by a semicolon (;) and must
be terminated by either a colon (:) or a period (.).
The colon signifies that more parameter/value pairs for
the current category are to follow; therefore, more than
one parameter/value pair may be given for the current
category. The period denotes the end of parameter/
value pairs for the given category.
Parameter/value pairs must not exceed 25 characters
with the semicolon and terminator included.
PTX_Setup