Printronix ThermaLine Series Programmer's Reference Manual page 117

Thermaline series
Table of Contents

Advertisement

Example
The following sample program specifies three logo calls placing the same
logo at three different locations. (The logo was previously defined and
stored.) The starting row and column specify the upper left corner of the
grid in which the logo was defined. To illustrate positioning, the starting
row and column are indicated on the example but do not necessarily reflect
actual location on the page.
LOGO
56;35;HAND
56;50;HAND
56;65;HAND
STOP
SR 56
SC 35
When the logo to be executed is not found in memory, the default external
memory module is automatically searched. If the logo is found, it is loaded
into memory and execution resumes; otherwise, the "LOGO NOT FOUND"
error is printed.
NOTE: If an older application uses the disk parameter for the execute
Commands
SC 50
command, it is ignored and the above steps are taken.
SC 65
logocall.ex
4–73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermaline igpThermaline pgl

Table of Contents