Chapter 6: Verifying the Status of the Switches
94
6. Enter the WRITE command to save your change, as shown in
Figure 51.
awplus# write
Building configuration ...
[OK]
awplus#
Figure 51. Saving the Change with the WRITE Command
Note
If this is the initial management session of the switch, the WRITE
command automatically creates in flash memory a new
configuration file called DEFAULT.CFG in which it stores your
configuration change. You may change the name of the file or
designate a different file after you create the stack.
7. Restart the switch with the REBOOT command, as shown in
Figure 52.
awplus# reboot
reboot system? (y/n):
awplus#
Figure 52. Rebooting the Switch with the REBOOT Command
8. Type "Y" for yes.
9. Wait one minute for the switch to initialize its management software.
10. Check the ID LED and do one of the following:
If the ID LED is displaying a number from 1 to 8, VCStack is now
enabled on the switch. Go to Chapter 7, "Installing the Stacking
QSFP+ Transceivers" on page 99.
If the ID LED is still displaying "0," repeat this procedure. If the
procedure was not successful, it might be because you did not
issue the WRITE command in step 5 to save your change.