Chapter 9: Cabling the Networking Ports
122
6. Verify the position of the handle on the transceiver. If the transceiver is
in a top slot, the handle should be in the upright position, as shown in
Figure 70. If the transceiver is in a bottom slot, the handle should be in
the down position.
SFP Handle
Figure 70. Positioning the SFP or SFP+ Handle in the Upright Position
7. Connect the fiber optic cable to the transceiver, as shown in Figure 71.
The connector on the cable should fit snugly into the port, and the tab
should lock the connector into place.
Figure 71. Connecting a Fiber Optic Cable to an SFP or SFP+ Transceiver
8. Repeat this procedure to install additional transceivers.