Installing the link

Connect to the web management interface

See
Connecting to the web management interface

Check ODU status

ODU status is indicated by the ODU Status attribute in the Status screen of the web
interface.
Check the ODU status attribute and take action as described in

Table 7-8 ODU status checks

ODU status attribute
OK
Download In Progress
No Response
Power Supply Fault
ODU Fault
Incompatible Device
Incompatible Firmware Version

Transmitter status

Transmitter status is indicated by the Transmitter Status attribute in the Status
Screen of the web interface and in Step 6: Antenna Alignment of the Installation
Wizard.
The transmitter is muted by default. The transmitter is enabled automatically
during installation in Step 6: Antenna Alignment of the Installation Wizard. The
transmitter may additionally be enabled or muted using the Configuration page of
the web interface.
phn-1478_005v000
Apr 2010
on page
Likely cause and action
The ODU is available for use. Continue at
Transmitter status
The CMU is downloading updated firmware
to the ODU. Wait for the download to
complete.
The ODU is not responding to management
messages from the CMU.
The CMU cannot power the ODU.
The ODU is reporting a fault condition.
The ODU firmware is not compatible with
the CMU. Replace the ODU.