Managing Faults; Configuring The Cmu To Generate Snmp Notifications - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

Managing faults

Managing faults

Configuring the CMU to generate SNMP notifications

Perform this task to enable the CMU to generate Simple Network Management
Protocol (SNMP) traps.
If SNMP is enabled, then the CMU generates SNMP traps when certain events
occur, and sends the traps to the network SNMP management agent, which notifies
the system administrator. The CMU may be configured to generate SNMP
notifications for the following events:
x
Cold start
x
Link status change
x
Diagnostic alarms
To configure SNMP notifications, proceed as follows:
Procedure 6-22 Configure SNMP notifications
1
From the left hand menu, select Remote Management. The Remote
Management page is displayed
Update the SNMP attributes
2
Select Submit Updated Configuration. The Configuration Change Reboot
3
dialog is displayed
4
Select Reboot Wireless Unit. The Reboot Confirmation dialog is displayed
(Figure
5
Select OK. The reboot progress message is displayed. On completion, the
unit restarts.
NOTE
6-44
(Figure
6-14).
If the 'Enabled Diagnostic Alarms' option is selected, ensure that the
required diagnostic alarms are enabled. For more information, see
Configuring generation of diagnostic alarms
(Figure
6-22).
(Table
6-16).
6-20).
Chapter 6 Operation
on page 6-47.
phn-1478_005v000
Apr 2010

Advertisement

Table of Contents
loading

Table of Contents