Check The Copper Data Port Ethernet Connection; Table 7-5 Copper Data Port Indicator Checks - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave
x
The Ethernet ports have compatible auto negotiation and duplex settings as
described in
If these steps fail to resolve the problem, continue at
7-12, selecting the option to reset IP and Ethernet configuration.

Check the copper Data port Ethernet connection

Check the state of the copper Data port indicators and take action as described in
Table
7-5.

Table 7-5 Copper Data port indicator checks

Copper Data
port indicator
state
Yellow steady,
green steady
Yellow flash,
green flash
Off
Copper Data port indicator is off
If the Copper Data port indicator is off, it means that the Ethernet link is down.
If the CMU copper data port is connected to a network, check the following:
x
The associated network equipment (workstation, PC, router, switch etc.) is
powered up and operating correctly.
x
The Ethernet port in the associated equipment is enabled.
x
The Ethernet cable between the CMU and the network equipment is
connected and is not damaged. If possible, substitute a known good Ethernet
cable.
x
The Ethernet ports have compatible auto negotiation and duplex settings as
described in
If the CMU Data port is connected directly to a PC, check the following:
x
The Ethernet port in the PC is enabled.
x
The Ethernet cable between the CMU and the PC is connected and is not
damaged. If possible, substitute a known good Ethernet cable.
x
The Ethernet ports have compatible auto negotiation and duplex settings as
described in
phn-1478_005v000
Apr 2010
Configuring the Ethernet ports
The Ethernet link is up but is not carrying traffic. Continue
at
Check IP network connection
The Ethernet link is up and is carrying traffic. Continue at
Check IP network connection
The Ethernet link is down. Continue at
indicator is off
on page 7-5.
Configuring the Ethernet ports
Configuring the Ethernet ports
Connecting to the web management interface
on page 6-24.
Recovering the CMU
Likely cause and action
on page 7-7.
on page 7-7.
on page 6-24.
on page 6-24.
on page
Copper Data port
7-5

Advertisement

Table of Contents
loading

Table of Contents