Check Browser Settings; Table 7-7 Ping Response Checks - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

Connecting to the web management interface

Table 7-7 Ping response checks

Ping response
Reply
Request timed out

Check browser settings

If there is IP connectivity between the CMU and the management PC or
workstation, but web-pages cannot be displayed, check that browser settings are
appropriate for the PTP 800 web interface.
7-8
Likely cause and action
The IP network is providing connectivity between the PC
and CMU. Continue at
8.
There is no IP connectivity. Check network configuration
including IP addresses, gateway address, subnet masks,
VLAN membership in network equipment between the PC
and the CMU. Check if the PC can reach other equipment
in the same network.
If these steps fail to resolve the problem, continue at
Entering recovery mode
option to reset IP and Ethernet configuration.
Chapter 7 Troubleshooting
Check browser settings
on page 7-12, selecting the
phn-1478_005v000
on page
7-
Apr 2010