Electromagnetic Compliance; Emc Immunity Compliance; Table 4-91 Emc Immunity Compliance Specifications - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave

Electromagnetic compliance

EMC immunity compliance

The PTP 800 has been tested for compliance to the EMC immunity specifications
listed in
The top level Specification is ETSI 301-489.

Table 4-91 EMC immunity compliance specifications

EN 55082-1 Generic EMC and EMI
requirements for Europe
EN 61000-4-2: 2001 Electro Static
Discharge (ESD), Class 2, 8 kV air, 4
kV contact discharge
EN 61000-4-3 (2006) Radiated
Immunity 3 V/m
EN 61000-4-4: 2004 (Bursts/Fast
Transients), Class 4, 4 kV level
(power lines AC & DC)
EN 61000-4-5 (2006) Surge Immunity
EN 61000-4-6: 1996 (Injected RF),
power line, Class 3 @ 10 V/m
phn-1478_005v000
Apr 2010
Table
4-91.
Specification
Comment
The levels used for testing were
increased to show ensure immunity
to 15kV air and 8kV contact
discharges.
Equipment was tested with level
increased for dc input and signal
lines @ 0.5 kV open circuit voltage.
Signal lines, Class 3 @ 3 V RMS un-
modulated.
Electromagnetic compliance