Figure 5-21 Cable Loss Plot For A 100 Meter Cable With No Odu; Figure 5-22 Cable Loss Plot For A 100 Meter Cable With Odu Connected - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

Testing the installation

Figure 5-21 Cable loss plot for a 100 meter cable with no ODU

0
-5
-10
-15
-20
-25
-30
300
Resolution: 517
Std: ---
Date: 11/11/2009
Model: S311D

Figure 5-22 Cable loss plot for a 100 meter cable with ODU connected

0
-5
-10
-15
-20
-25
-30
300
Resolution: 517
Std: ---
Date: 11/11/2009
Model: S311D
5-82
M1: -9.08 dB @ 350.00 MHz
310
320
330
Frequency (300.0 - 400.0 M Hz)
M1: -16.74 dB @ 350.00 MHz
310
320
330
Cable Loss
NO ODU 100M
M 1
340
350
360
CAL:ON(COAX)
Channel: N/A
Time: 03:43:56
Serial #: 00936036
Cable Loss
ODU 100M
M 1
340
350
360
Frequency (300.0 - 400.0 M Hz)
CAL:ON(COAX)
Channel: N/A
Time: 03:45:03
Serial #: 00936036
Chapter 5 Installation
370
380
390
400
CW: ON
Avg.CableLoss: 8.97 dB
370
380
390
Avg.CableLoss: 17.89 dB
phn-1478_005v000
400
CW: ON
Apr 2010