Figure 6-26 Clock Section Of Remote Management Page (Sntp Enabled); Table 6-20 Sntp Clock Attributes - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

Managing faults

Figure 6-26 Clock section of Remote Management page (SNTP enabled)

Table 6-20 SNTP clock attributes

Attribute
SNTP State
SNTP Server IP
Address
SNTP Server Port
Number
SNTP Poll Interval
SNTP Sync
System Clock
Time Zone
Daylight Saving
6-54
'Enabled' means that the CMU will obtain accurate date
and time updates from a networked time server.
Enter the IP address of the networked SNTP server.
Enter the port number of the networked SNTP server. By
convention the default value for the port number is 123.
Enter the period at which the SNTP client polls the
server for time correction updates (default 1 hour). If an
SNTP poll fails, the client will automatically perform
three retries before waiting for the user defined poll
period.
This shows the current status of SNTP synchronization. If
'No Sync' is displayed, then review the SNTP Server IP
Address and Port Number. A change of state may
generate an SNMP trap or SMTP email alert.
This displays the local time, allowing for the Time Zone
and Daylight Saving settings.
Set the time zone offset from Greenwich Mean Time
(GMT).
'Disabled' means that daylight saving adjustments will
not be applied to the time.
'Enabled' means that daylight saving adjustments will be
applied to the time, according to local rules.