Status attributes
The System Status page contains a number of status attributes. These are
highlighted in green for normal operation, or in red to indicate abnormal operation.
The following attributes are defined:
x
ODU Status
x
Transmitter Status
x
Data Port Status
x
Management Port Status
x
Wireless Link Status

Table 6-2 ODU Status attribute values

OK
Fault
Incompatible License
In Reset
Download In Progress
Incompatible Firmware
Version
Incompatible Device
IF Card Attached
No Response
Power Supply Fault
Power Supply Disabled
6-6
(Table
6-2).
(Table
(Table
(Table
Value
The ODU is ready for use.
The ODU has raised alarms, but the CMU makes its best
effort to carry on.
The configured radio license is not compatible with this
ODU. The ODU remains muted.
The ODU is booting. This state is transient during CMU
boot or after firmware download.
New ODU firmware is being downloaded. Percentage
completion is shown here.
The ODU firmware is too old. If possible, download will
begin.
The connected device is an ODU, but it is not a Motorola
branded product.
The connected device is an IF card, not an ODU.
No response can be detected from the ODU. It is
probably not connected.
The power supply to the ODU is at fault (short
circuited).
The power supply to the ODU is disabled. It can only be
enabled by Motorola.
6-3).
6-4).
(Table
6-5).
6-6).
Chapter 6 Operation
Meaning
phn-1478_005v000