ND detection configuration commands

display ipv6 nd detection

Syntax
display ipv6 nd detection [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, seethe Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use the display ipv6 nd detection command to display ND detection configuration.
Related commands: ipv6 nd detection enable and ipv6 nd detection trust.
Examples
# Display ND detection configuration.
<Sysname> display ipv6 nd detection
ND detection is enabled on the following VLANs:
1, 2, 4-5
ND detection trust is configured on the following interfaces:
Ethernet1/0/1
Ethernet1/0/2
Table 52 Output description
Field
ND detection is enabled on the
following VLANs
ND detection trust is configured on the
following interfaces
Description
List of VLANs enabled with ND detection.
List of ND-trusted ports. On an ND-trusted port, ND packets are not
checked. By default, all ports are ND-untrusted ports on which ND
packets in an ND detection-enabled VLAN will be checked.