Digital Input 1 – If DIN1 voltage becomes equal or higher than 7,5 V it will disable
AutoGeofenze Zone.
Power Voltage – if power voltage become higher that low voltage level (Ignition
settings) it will disable AutoGeofenze Zone.
Engine RPM – If engine RPM became higher that 0 it will disable AutoGeofence
Zone.
Feature – Priority of generated event, which will be applied to saved record.
Enter Event – Event generation on Geofence entrance.
Exit Event – Event generation on Geofence exit.
On Both - Event generation on Geofence entrance Or exit
Eventual Records – Enable or Disable Eventual Records functionality.
Note that AutoGeofencing does not require entering coordinates, instead it requires GPS
visibility. If vehicle stopped and activation timeout has passed, an AutoGeofence will be created
around vehicle's last position with set Radius value.

5.12 Manual Geofence

FMB920 has 50 configurable Geofence zones and it can generate an event when defined
Geofence zone border is crossed.
Frame border – frame border is an additional border around Geofence zone. It is additional
area around defined zone used to prevent false event recording when object stops on the border
of the area and because of GNSS errors some records are made inside area and some – outside.
Event is generated only when both borders are crossed. See figure 26 for details: blue track is
considered to have entered the area while red track is not.
Figure 25 Auto Geofence configuration