5.21.2 Operand On Entrance
Record is generated when actual value input is between high and low level values.
5.21.3 Operand On Both
Record is generated when actual value input increases or decreases and becomes higher or
lower than high or low level values.
Current value < Low level
or
Current value > High level
5.21.4 Operand Monitoring
No event at all. Values are recorded only when other trigger have worked.
5.21.5 Operand On Hysteresis
Record is generated when actual value input becomes higher than high level value and
decreasing becomes less than low level value.
Current value >= Low level
or
Current value <= High level
Figure 43 On Entrance operand logic
Current value >= Low level
Current value <= High level
Figure 44 On Both operand logic
Wait other events
Figure 45 Monitoring operand logic
Generate record
or
Generate record
Generate record
63