Minimum
Maximum
value
value
0
1

7.12.5 I/O#1 Event only (ID=50004)

Parameter defines when IO element value is sent: 0 – with every AVL packet, 1 – on event
only. On event means that IO element value is included to AVL packet only when this particular
event happens. With regular, periodic records such IO element value is not included.
Minimal
Maximum
value
value
0
1

7.12.6 I/O#1 averaging length (ID=50005)

Parameter defines I/O property sample length to average.
Minimum
Maximum
value
value
0
65535

7.12.7 I/O#1 send SMS (ID=7000)

Enable/disable sms event sending. 0 – Disable, 1-10 – sms will be sent to configured GSM
number.
Default value
Goes with (depends on)
I/O#1 property parameter priority
I/O#1 operand (ID=50001)
I/O#1 High level (ID=50002)
0
I/O#1 Event only (ID=50004)
I/O#1 averaging length (ID=50005)
I/O#1 send SMS (ID=7000)
I/O#1 SMS text (ID=8000)
Default value
Goes with (depends on)
I/O#1 property parameter priority
I/O#1 High level (ID=50002)
0
I/O#1 Low level (ID=50003)
I/O#1 averaging length (ID=50005)
I/O#1 send SMS (ID=7000)
Default value
Goes with (depends on)
I/O#1 property parameter priority
I/O#1 High level (ID=50002)
10
I/O#1 Low level (ID=50003)
I/O#1 Event only (ID=50004)
I/O#1 send SMS (ID=7000)
parameters
Ignition (ID=50000)
parameters
Ignition (ID=50000)
I/O#1 operand (ID=50001)
I/O#1 SMS text (ID=8000)
parameters
Ignition (ID=50000)
I/O#1 operand (ID=50001)
I/O#1 SMS text (ID=8000)
Value
type
Uint8
Value
type
Uint8
Value
type
Uint16