Digital output No.1 is activated for a period of time to warn driver. Output on-time
should/can be configured separately for each case.
*Example. If acceleration harsh event of 3.55 m/s2 detected. Record with value 3.55*10 = 35.5
≈ 36 will be saved ant sent to server.
5.10.1.2
1. Vehicle stopped
2. Road is straight
3. Send SMS "auto_calibrate"
4. Accelerate to > 30 km/h for 5 sec.
5. FMB will send response when calibration is success.
Calibration is saved to Internal Flash, after restart should be the same
To check autocalibration status send: position_info
To zero out accelerometer axis SMS: "calibrate", can be used, vehicle speed must be 0
km/h.
5.10.2 Over Speeding
Scenario is activated and DOUT1 is ON, when vehicle speed exceeds parameter value.
Scenario is activated until current speed decreases below parameter value.
5.10.3 Excessive Idling
Scenario is activated and DOUT1 is ON, when vehicle stops for specific amount of time. You
can configure time it takes to turn on this scenario (Time to Stopped). Scenario is activated until
vehicle starts moving and keeps moving (moving is detected only from accelerometer) for
amount of time that is configured. You can configure time it takes to turn OFF this scenario (Time
to Stopped).
5.10.4 Jamming
Scenario is activated and DOUT1 IS ON, then jamming is detected.
Jamming timeout time can be configures. After Jamming trigger count configured timeout
(in seconds), DOUT1 control and jamming event will be generated after this timeout. If Jamming
ends during timeout counting no event will be generated and output will not be controlled.
You can configure eventual records parameter: when he is disabled scenario status value
will be appeared in each AVL record, and when he is enabled scenario status value will be
appended only to eventual records.
5.10.5 Use authorized numbers to control DOUT via call
Scenario is activated and DOUT1 IS ON, when call is received from number who is in
authorized numbers list.
Call control
When FMBXX is configured to control DOUT1 device waits incoming call from
Auto Calibaration
41