High Voltage Level (Id=104); Low Voltage Level (Id=105); Movement Start Delay(S) (Id=19001); Movement Stop Delay(S) (Id=19002) - Teltonika FMB920 User Manual

Tracking terminal with gnss and gsm connectivity
Hide thumbs Also See for FMB920:
Table of Contents

Advertisement

15 – Digital Input, Accelerometer, Power voltage and Engine RPM
Minimum
Maximum
value
value
1
15
7.1.9

High voltage level (ID=104)

Sets high level of voltage.
Minimum
Maximum
value
value
0
(but
higher
30000
than low
level)

7.1.10 Low voltage level (ID=105)

Sets low level of voltage.
Minimum
Maximum
value
value
29999
(but lower
0
than high
level)

7.1.11 Movement Start Delay(s) (ID=19001)

What Acceleromer Ignition source delay will be after Ignition on.
Minimum
Maximum
value
value
1
60

7.1.12 Movement Stop Delay(s) (ID=19002)

What Accelerometer Ignition source delay will be after Ignition off.
Minimum
Maximum
value
value
Default value
Goes with (depends on)
High voltage level (ID=104)
Low voltage level (ID=105)
Movement Start Delay(s)
4
Movement Stop Delay(s)
Default value
Goes with (depends on)
Ignition settings (ID=101)
30000
Low voltage level (ID=105)
Default value
Goes with (depends on)
Ignition settings (ID=101)
13200
High voltage level (ID=104)
Default value
Goes with (depends on)
Ignition settings (ID=101)
1
Movement Stop Delay(s)
Default value
Goes with (depends on)
parameters
(ID=19001)
(ID=19002)
parameters
parameters
parameters
(ID=19002)
parameters
Value
type
Uint8
Value
type
Uint16
Value
type
Uint16
Value
type
Uint8
Value
type
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmb900

Table of Contents