System Module (SMOD) Overview

CMOD0-7
Power Slots
CMOD 0
CMOD 2
CMOD 4
CMOD 6
CMOD1, CMOD3, CMOD5, and CMOD7 in slots 1, 3, 5, and 7 do not supply FM power.
See
"Servicing Fan Modules (CRU) and Fan Frames (CRU)" on page
System Module (SMOD) Overview
These topics provide information about server system modules (SMODs) and components.
"SMOD Components" on page 36
"SMOD Motherboard" on page 38
"Server Storage Drives" on page 39
SMODs are internal cold-service components, back panel accessible.
The Oracle Server X7-8 SMOD features are:
Two SMODs are installed in the chassis: SMOD0 and SMOD1.
One Intel Xeon C624 Chipset Platform Controller Hub (PCH).
One Internal PCIe slot for RAID storage HBA connectivity to drive bays.
This PCIe slot is populated by one PCIe Gen3 x8 HBA per SMOD (Oracle Storage
12Gb SAS PCIe RAID HBA, Internal 16-Port). Four ports in the card are used for SAS
connectivity.
One service processor (on SMOD): Emulex Pilot 4 service processor (SP).
SP characteristics:
34
Oracle Server X7-8 Service Manual • October 2017
FM0-6 Fan Modules Powered
FM0 and FM1
FM2 and FM3
FM4 and FM5
FM6 and FM7
Remote keyboard, video, mouse (KVM) redirection
Full remote management through command-line, IPMI, and browser interfaces
Remote media capability (DVD, CD, ISO image)
Advanced power management and monitoring
Active Directory, LDAP, RADIUS support
129.