Remove a Fan Module
Call
Out
1
2
3
To unlock the fan module, push in the green release button.
3.
Caution -
is in Main power mode. This action removes power from the CMODs and causes an immediate
shutdown. On an eight-CMOD system, this applies to all fan modules. On a four-CMOD
system, this applies to the fan modules in the left-side fan frame.
4.
To remove the fan module, pull it out of the slot.
132
Oracle Server X7-8 Service Manual • October 2017
Status LED or Button
Fault-Service Required
OK
Release button
Data Loss. Do not remove more than one fan module from a column while the system
Icon
Description
and
Color
Indicates a fault state in a fan module:
■ Off – Fan module is operating normally,
■ Steady On – A fault is present in the fan module.
Amber
Indicates the functional state of the fan module:
■ Steady On – Fan module is powered on and
functioning normally.
■ Off – Fan module is powered off and not functioning.
Green
None
Press the green button to release and remove the fan
module.