2.
Ensure that the AC power cord for the power supply slot is connected and
secured.
The power cord connects at the back of the server.
3.
Open the power supply lever. Squeeze together the two green release latches at
the end of the lever and rotate the lever to the left.
Access this component directly from the front of the server. Ensure that the power supply lever
is in its fully open position.
4.
Align the power supply with its slot.
Ensure that the connector end of the PS is at the opening of the slot and that the open hinge on
the front of the PS is at the bottom and to the left.
5.
Slide the power supply into the slot until it stops.
To install the power supply, rotate the lever to the right (1).
6.
The pawl at the hinged end of the lever engages the sidewall of the server and provides the
pivot point for the leverage necessary to draw the power supply into the slot and engage the
internal connector. The two green release latches at the end of the lever engage to secure the
power supply in place (2).
Install a Power Supply
Servicing Components
145