Do not swap "R" or "T" wires with ground
wire inside power supply junction box. Doing
so will electrify machine frame, which could
cause electrocution. Make sure incoming
ground wire is only connected to right-most
terminal post in the power supply junction
box so machine is properly grounded.
7.
Press Emergency Stop button on front of
machine to turn machine OFF.
8.
WITHOUT resetting Emergency Stop button,
press either ON button. Machine should not
start.
—If machine does start (with Emergency Stop
button pushed in), immediately disconnect
power to machine. Emergency Stop button
safety feature is not working correctly. This
safety feature must work properly before
proceeding with regular operations. Call
Tech Support for help.
9.
Reset Emergency Stop button on front of
machine.
10. Repeat Steps 7–9 with Emergency Stop but-
ton on side of cabinet. Congratulations. Test
Run is complete!
-42-
Recommended
Adjustments
The following list of adjustments were performed
at the factory before the machine was shipped:
Riving Knife Alignment ................... Page 46
Aligning Scoring Blade ................... Page 53
Blade Tilt Calibration .......................Page 74
Sliding Table Parallel Adjustment ....Page 75
Sliding Table Movement Adjustment
........................................................Page 76
Squaring Crosscut Fence to Blade
........................................................Page 76
Calibrating Rip Fence ......................Page 79
Be aware that machine components can shift
during the shipping process. Pay careful atten-
tion to these adjustments during operation of the
machine. If you find that the adjustments are not
set according to the procedures in this manual or
your personal preferences, re-adjust them.
Model G0764Z (Mfd. Since 10/15)