CMC Connector Ports and Indicators
System Power Status
007-5806-004
•
Monitors the On/Off power sequence
•
Monitors system resets
•
Applies a preset voltage to switch blades and fan control boards
The ports on the CMC board are used as follows:
•
CMC-0 - Primary CMC connection, connects to the RLC via the 48-port management
switch
•
CMC-1 - Secondary CMC connection to the RLC via the 48-port management switch (used
with redundant VLAN switch configurations)
•
ACC - Accessory port, used as a direct connection to the microprocessor for service
•
CNSL - Console connection - used primarily for service troubleshooting
•
RES - RESET switch, depress this switch to reset the CMC microprocessor
•
HB - Heartbeat LED, lighted green LED indicates CMC is running
•
PG - Power Good LED, this LED is illuminated green when power is present
Figure 2-5 shows the chassis management controller front panel in the blade enclosure.
CMC-0
CMC-1
Figure 2-5
Chassis Management Controller Board Front Panel Ports and Indicators
The cpower command is the main interface for all power management commands. You can
request power status and power-on or power-off the system with commands entered via the
administrative controller server or rack leader controller in the system rack. The cpower
ACC
CNSL RES HB PG
System Power Status
23