8. Appendix: SP Mode Tables
• Medium: Center of the range (default)
• Strong: High end of the range.
5 MTF: 0 (Off) 1-15 (Weak – Strong)
6 Smoothing 0 (x1) 1 – 7 (Weak – Strong)
7 Brightness: 1 – 255
8 Contrast: 1 – 255
9 Ind Dot Erase: 0 (x1) 1 – 7 (Weak – Strong)
4700
Display the ID of ASIC
This SP displays the ID of ASIC or FPGA_A0 after an error occurs and causes SC144 (CIS
Communication Error).
Note: This SP displays after SC144 is issued if the reading of the ID value is not within
specifications for automatic CIS adjustment control.
1 CIS: ASIC_1
Reads and displays the ID of ASIC_1 (Marble 1) where an error was detected during
automatic CIS adjustment.
8
2 CIS: ASIC_2
Reads and displays the ID of ASIC_2 (Marble 2) when an error was detected during automatic
CIS adjustment.
3 CIS: ASIC_3
Reads and displays the ID of ASIC_3 (Marble 3) when an error was detected during automatic
CIS adjustment.
4 FPGA_A0
Reads and displays the ID of FPGA_A0 when an error was detected during automatic CIS
adjustment.
Periodic Adjustment Setting DFU
4701
This SP sets the CIS read cycle for lines in the main scan direction.
[0 to 65535/14455/1]
142
[0 to 15/8/1
[0 to 7/0/1]
[1 to 255/128/1]
[0 to 7/0/1]