7. With the drawer open, loosen the roll feeder positioning brackets:
[A] On the left ( x2)
[B] On the right ( x2)
8. Pull out the lower roll feeder drawer completely.
9. Pull out the flat cable [A] as far as it will reach.
10. Set the cable in flat clamp [B] and [C], then close the clamps.
11. Open the harness clamps ( x7) and flat clamp [D].
12. Close the clamps over the flat cable and connect the flat cable at [E] to CN230 of the IOB ( x8,
 x1)
Roll Feeder Type 7140 (D394)