8. Appendix: SP Mode Tables
• SP2401-5 controls current timing to areas other than the leading edge of cut sheet
[-30 to 30/19/1]
2402
Separation AC Current Adjustment
Adjusts the separation ac voltage setting. DFU
1 Roll Paper
2 Cut Paper
Separation DC Current Adjustment DFU
2403
Adjusts the separation dc voltage. If the setting is too high, toner will be re-attracted from the
paper to the drum after transfer.
SP2403 Settings Table
Source
1
2
8
3
Roll
4
5
6
11
12
13
Cut
14
15
16
2602
PTL Adjustment DFU
124
paper.
[18 to 466/280/1 uA]
Type
Area
Leading Edge
Plain
Image Area
Leading Edge
Trans
Image Area
Leading Edge
Film
Image Area
Leading Edge
Plain
Image Area
Leading Edge
Trans
Image Area
Leading Edge
Film
Image Area
[Range/Default/Step]
[0 to 80/40/0.1 uA]
[0 to 80/30/0.1 uA]
[0 to 80/50/0.1 uA]
[0 to 80/40/0.1 uA]
[0 to 80/b/0.1 uA]
[0 to 80/60/0.1 uA]
[0 to 80/30/0.1 uA]
[0 to 80/0/60.1 uA]
[0 to 80/0/40.1 uA]
[0 to 80/0/0.1 uA]