4. Appendix: Preventive Maintenance
Tables

PM Tables

Letter
A
Adjust
C
Clean
I
Inspect
L
Lubricate
R
Replace
Units of measure in the PM Interval column: 1 m = 3.28 ft.

Main Machine (D046/D049)

Original Feed
Item
Original Feed Roller
Original Exit Roller
Original Set Sensor
Original Registration Sensor
Original Table
Optics
PM
Interval
m
ft.
10K
32.8K
196.8
60K
K
10K
32.8K
PM
Comment
C
Alcohol or water, dry cloth
C
Blower brush
C
Water, dry cloth