2. Installation
7. At the left rear corner of the main machine, measure the distance [A] between the bridge unit and the
main machine. (This should be about 49.5 to 50 mm.)
2
8. At the right rear corner of the main machine, measure the distance [B] between the bridge unit and
the main machine. (This should be about 49.5 to 50 mm.)
9. The difference between the measured distances on the left and right ([A] – [B]) must not be more than
0.5 mm.
138