Ricoh BE-C1 D046 Field Service Manual page 140

Table of Contents

Advertisement

2. Installation
7. At the left rear corner of the main machine, measure the distance [A] between the bridge unit and the
main machine. (This should be about 49.5 to 50 mm.)
2
8. At the right rear corner of the main machine, measure the distance [B] between the bridge unit and
the main machine. (This should be about 49.5 to 50 mm.)
9. The difference between the measured distances on the left and right ([A] – [B]) must not be more than
0.5 mm.
138

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be-c1 d049

Table of Contents