Ricoh BE-C1 D046 Field Service Manual page 579

Table of Contents

Advertisement

[0 to 2/1/1]
0: Synchronized with driving motor
Fan operation is synchronized with main motor or fusing motor.
• The left, right motors go ON when the main motor, fusing motor start-up (whichever is
first) goes ON.
• Left, right motors go OFF when the main motor or fusing motor goes OFF (whichever goes
OFF second).
1: Off
2: Synchronized with power relay. Synchronized with the operation of the fusing lamps (OFF
when an SC is issued and when the upper unit is open.)
LED Duty Adjustment
2943
Adjusts the LED duty level for each LPH.
1 LPH1
2 LPH2
3 LPH3
2952
LPH Joint Adjustment
These SP codes adjust the scanning at the points of the LPH joints.
Note: Do these adjustments only after replacing the LPH>
SP2952 Settings Table
1
LPH-2
2
LPH-3
11
LPH-2
12
LPH-3
2954
Binary Line Width Correction: Print
These SP's determine how line processing is handled for vertical lines.
Note: This SP has no effect on horizontal lines.
[24 to 80/72.8/0.2 us]
Scan
Paper
Main
All
Sub
Joint
[Range/Default/Step]
LPH1, 2
[0 to 999/500/1]
LPH2, 3
LPH1, 2
[300 to 500/412/1]
LPH2, 3
[2 to 100/16/1]