Ricoh BE-C1 D046 Field Service Manual page 533

Table of Contents

Advertisement

1 Hot Roller Temperature
2 Pressure Roller Temperature: Center
3 Pressure Roller Temperature: Edge
4 Hot Roller Temperature: Edge
1159
Fusing SC Settings
This SP determines whether the machine stops and displays an SC if three consecutive jams
occur in the fusing unit.
[0 to 1/0/1]
0: Disable. SC code is not displayed.
1: Enable. SC code is displayed.
1801
Motor Speed Adjustment DFU
These speeds of the motors below can be adjusted by the percentage entered.
• D046 120 mm/s
• D049 170 mm/s
• Raising the setting in the plus direction increases speed, lowering the setting in the minus
direction lowers speed.
1 Feed Motor: 1st Roll
2 Feed Motor: 2nd Roll
3 Feed Motor: 3rd Roll
4 Feed Motor: 4th Roll
5 Feed Motor: Cut Paper Tray
6 Registration Motor
7 Fusing Motor
Black Core Full Paste
1901
D046 only
Adjusts the feed motor speed.
[D046: [-5 to +5/-0.4./0.1% ]
[D049: [-5 to +5/-0.2./0.1% ]
[-5 to +5/0/0.1%]
Adjusts the registration motor speed.
[-5 to +5/0/0.02%]
Adjusts the fusing motor speed.
D046: [-5 to +5/0.8/0.01%]
D049: [-5 to +5/0.3/0.01%]
System Service Mode